Introduction to Data Communications | ||
---|---|---|
Previous | 45i. Token Ring Cabling (cont'd) | Next |
Type 1
Two shielded, solid wire, twisted pairs, 22 AWG. Available for plenum or nonplenum interior use and underground or aerial exterior use. Use of Type 1 permits transmission at 16 Mbps and a maximum of 260 stations on the network.
Note: Plenum is heating ducts and air returns. To be qualified for plenum installation means that it must meet certain standards for releasing hazardous fumes and temperature ratings.
Type 2
Two shielded, solid wire twisted pairs, 22 AWG plus four twisted pairs of solid 26 AWG wires added between the shield and the insulating cable sheath. Type 2 supports 16 Mbps transmission.
Type 3 (RJ11 and RJ45)
Unshielded, telephone grade (22 or 24 AWG) twisted pairs, typically found inside a building. Basically equivalent to Cat 5 cable. See previous section on Unshielded Twisted Pair cabling.
Type 5
100/50 micron fibre-optic cable, used to connect distant MSAUs with fibre optic repeaters.
Type 6
Patch cables consisting of data-grade, stranded, shielded twisted pairs, 26 AWG. the distant limits are 66% of Type 1 cable.
Type 8
Under carpet cable, data-grade twisted pair cable, 26 AWG. The distance limits are 50 percent of Type 1.
Type 9
Shielded twisted pair, 26 AWG approved for plenum installations. The distance limits are 66% of Type 1 cable.