MSAU Relay

When a Token Ring NIC is first turned on, it goes through a process called Ring Insertion. It checks the Lobe to see if the wiring is okay and then applies a DC voltage on the Transmit pair of wires. The DC voltage is often called phantom power.

This voltage energizes a relay in the MSAU and attaches the Lobe to the ring. If you disconnect a cable at the MSAU, the relay will de-energize and automatically disconnect the lobe from the ring. You can actually hear the relays clicking in and out.


Ring In/ Ring Out

On a MSAU are 2 connectors called Ring In (RI) and Ring Out (RO). These are used for connecting MSAUs together. Two pairs of wires are run between MSAUs to connect them together, one pair is used for the Main Ring and one is used for the Backup Ring.

The following figure indicates the Main Ring and the Backup Ring. Notice that the Backup Ring runs in parallel with the Main Ring and is not normally used. Also notice that the direction of data flow on the Backup Ring is opposite to the Main Ring.